    AirDaddy Labs Testing Methodology

    The full protocol behind every AirDaddy Labs measurement — room sizes, durations, instruments, repeatability and scoring.

    By the AirDaddy Editorial Team Last updated: 8 September 2026

    Protocol

    How products are tested

    Every product follows the same five-stage sequence. Nothing is published from a single run, and no figure is published that was not logged by an instrument.

    Standard test sequence
    1. 1

      Baseline: 30 minutes of ambient logging with the unit off, doors and windows closed.

    2. 2

      Event: a controlled, repeatable particulate release appropriate to the test type.

    3. 3

      Run: the unit operates at the stated speed for 60 minutes while PM2.5 and PM10 are logged each minute.

    4. 4

      Recovery: decay curve compared against the unaided settling curve from the same room.

    Each condition is repeated a minimum of three times on separate days. Runs that deviate by more than 15% from the median are investigated before inclusion.

    Environment

    Room sizes

    UK homes are smaller than the North American rooms most coverage claims assume. We standardise on three rooms with 2.4 m ceilings, and we always state which room a result came from.

    Test roomFloor areaVolumeTypical use
    Small bedroom~9 m²~22 m³Box rooms, nurseries
    Standard double bedroom~12–14 m²~29–34 m³Overnight and sleep testing
    Living room~20–25 m²~48–60 m³Dust, pets, open-plan behaviour

    Timing

    Measurement duration

    30 minutes baseline, 60 minutes run, 30 minutes post-run for standard purification tests. Overnight bedroom tests log continuously for nine hours (22:00–07:00). Filter longevity observations run for a minimum of 90 days of normal household use.

    Instruments

    PM2.5 monitoring

    Particulate readings are logged at one-minute resolution at seated or bedside breathing height, at least 1.5 m from the purifier's outlet so we measure the room rather than the exhaust. A second monitor records the same room as a cross-check, and both are co-located for a 24-hour agreement check before each study.

    Readings are reported in µg/m³ against the WHO 2021 guideline values (5 µg/m³ annual mean, 15 µg/m³ 24-hour mean) rather than a proprietary index, so they can be compared with public data.

    Monitor co-location agreement check

    Data collection begins soon.

    Published with each study: 24-hour agreement between the reference and cross-check monitors.

    Acoustics

    Noise testing

    Sound is measured in dB(A) at 1 metre, at bedside height, in a furnished bedroom — not an anechoic chamber. We record the room's background floor first and discard any measurement taken when the floor is within 5 dB of the unit. Every fan speed is measured, and sleep mode is reported separately because it is the only speed most people will tolerate overnight.

    Cost

    Filter cost calculations

    Filter cost per year = (UK replacement filter price ÷ observed service life in months) × 12. We use the lowest widely available UK price for genuine filters at time of publication, exclude third-party filters from the headline figure, and note where a model requires separate HEPA and carbon stages.

    Cost

    Running cost calculations

    Electricity is metered at the plug on each speed. Annual cost = measured watts ÷ 1000 × hours per day × 365 × the prevailing Ofgem price-cap unit rate, with the rate and date always stated. Our default usage assumption is 12 hours per day on the speed needed for the stated room size.

    Study types

    Bedroom and dust testing

    Bedroom testing is an occupied overnight protocol: door closed, curtains drawn, purifier on sleep mode, with PM2.5, CO2, temperature and humidity logged from 22:00 to 07:00 and compared against a control night with the unit off.

    Dust testing uses repeatable disturbance events — bed-making, walking a carpeted route, and vacuuming — with PM10 and PM2.5 decay curves compared against unaided settling in the same room at the same time of day.

    Quality control

    Repeatability

    A result is only published when three separate runs on separate days agree within 15% of the median. Where they do not, we publish the spread rather than the average and say why. Outdoor conditions, indoor humidity and background PM2.5 are recorded for every run so readers can see the context a number was produced in.

    Scoring

    Scoring methodology

    PillarWeightBasis
    Clean air performance30%Measured PM2.5 decay rate in the stated room size
    Noise20%dB(A) at 1 m on sleep mode and at the speed needed for the room
    Running cost20%Metered watts × UK unit rate, plus filter cost per year
    Filter longevity & availability15%Observed service life against stated interval, UK stock
    Usability10%Controls, app behaviour, auto mode responsiveness, filter access
    Build & repairability5%Materials, serviceable parts, warranty terms

    Scores are out of 10 and recalculated whenever a price, filter cost or firmware behaviour changes materially. Affiliate revenue is not an input to any pillar.