Dust Tests
How household dust behaves in UK homes, and how AirDaddy Labs measures whether a purifier actually reduces it.
Disclosure: As an Amazon Associate, AirDaddy earns from qualifying purchases. Affiliate relationships never influence AirDaddy Labs test results or scoring.
Background
How dust behaves indoors
Household dust is a mixture of skin cells, textile fibres, soil tracked in on shoes, cooking aerosols, combustion particles and — in most UK homes — dust mite allergen. Its behaviour depends almost entirely on particle size.
Larger particles (roughly PM10 and above) settle within minutes. These are the fibres and flakes you see on a windowsill. Finer particles (PM2.5 and below) can stay airborne for hours, drift between rooms, and are the fraction associated with health effects in WHO and Defra guidance.
The practical consequence is that dust is not one problem. Filtration is highly effective against the airborne fine fraction and almost irrelevant against dust already sitting on a shelf — which is exactly the distinction manufacturer marketing tends to blur.
Method
How we measure dust reduction
- 1
30-minute closed-room baseline with the purifier off, background PM10 and PM2.5 recorded.
- 2
A repeatable disturbance: bed-making, a fixed carpet walking route, or a timed vacuum pass.
- 3
60 minutes of 1-minute logging as particles settle, once unaided and once with the unit running.
- 4
Decay curves compared; the difference in time-to-baseline is the published result.
Each condition is repeated on three separate days. Outdoor PM2.5, indoor humidity and room temperature are recorded for every run.
We deliberately do not use smoke sticks or incense as the dust source. They produce a clean, flattering decay curve that has little to do with how dust is actually generated in a home.
Instruments
How PM2.5 is tracked
Two monitors log the room: a reference unit at breathing height at least 1.5 m from the purifier outlet, and a cross-check unit on the opposite side of the room. Both are co-located for 24 hours beforehand so their agreement is known and published. Full instrument detail is on the AirDaddy Labs testing methodology page.
Publication
Future graphs, datasets and charts
PM10 decay after bed-making
Data collection begins soon.
Time to return to baseline, by room
Data collection begins soon.
Vacuuming: PM2.5 during and after
Data collection begins soon.
Open dust dataset (CSV)
Data collection begins soon.
These are placeholders for original AirDaddy Labs research. We publish no estimated, modelled or manufacturer-supplied figures as measurements. Data collection begins soon.